RS485 locker controller frames truncating under burst unlocks on Linux
DEV Community

RS485 locker controller frames truncating under burst unlocks on Linux

Hi everyone,

We are running an edge controller on Debian 12 (Raspberry Pi CM4, kernel 6.6.x) using Python 3.11 (pyserial) over a USB-to-RS485 FTDI adapter (/dev/ttyUSB0 @ 9600 baud) to drive modular 12V solenoid lock controller boards for an on-prem smart locker system.

Expected Behavior

When an employee scans an RFID badge or QR code at the kiosk, the Python daemon sends a 10-byte RS485 command frame to the target slave board, waits ~80ms for the door-sensor status ACK (0xAA 0x55 ...), and updates the local SQLite compartment state.

Actual Behavior

During shift changes - when multiple users trigger unlocks back-to-back or when our background door-state polling loop overlaps an unlock request - serial.read() returns partial 4-6 byte frames or times out, causing the daemon to log a false "door failed to open" state even though the solenoid physically clicked open.

Relevant snippet from our serial worker:

with serial_lock:
    ser.reset_input_buffer()
    ser.write(build_unlock_frame(board_id, slot_id))
    ser.flush()
    time.sleep(0.05)
    resp = ser.read(10)

Error logged via journalctl -u locker-daemon:

Nov 25 08:51:14 edge-node-02 locker-daemon[812]: WARNING: board=0x03 slot=14 short read (got 5/10 bytes): b'\xaa\x55\x03\x0e\x01'
Nov 25 08:51:14 edge-node-02 locker-daemon[812]: ERROR: CRC mismatch on compartment status poll, retrying frame

What We've Tried

  • Added a threading.Lock() around all RS485 bus reads/writes so polling and unlock commands don't collide in Python.
  • Lowered /sys/bus/usb-serial/devices/ttyUSB0/latency_timer from 16 to 1.
  • Increased timeout=0.3 on pyserial.Serial, which reduces timeouts slightly but still drops tail bytes when 3+ boards reply sequentially.

Is calling ser.reset_input_buffer() right before write() discarding delayed turnaround bytes from the RS485 transceiver, or should we switch from fixed-length ser.read(10) to a frame-header/CRC state machine reading byte-by-byte until the footer?

Read on DEV Community ↗ ← Back to News

Comments

No comments yet. Start the discussion.